Mfg Part Number: AFM120PS24 | NSN : 6120-01-600-9116 | NIIN : 016009116 |
CAGE Code : 1VWD9 | Manufacturer: Xp Power Inc | Item Name : Power Supply |
FSC : 6120 Transformers Distribution and Power Station |
Thank you for your interest in NSN Part AFM120PS24 under NSN 6120-01-600-9116 with 016009116 featured on After Market Aero Spares. On this page, entities may request a quote for their comparisons on Power Supply items by Xp Power Inc with the CAGE Code 1VWD9 or begin the purchasing process through the submission of a completed RFQ form. This entails providing details regarding one’s desired part quantities, target prices, estimated shipping time frames, and more, as applicable. Upon submitting a completed form for NSN Part AFM120PS24 with 6120 Transformers Distribution and Power Station our representatives will utilize their market prowess to supply you with a personalized quote backed by rapid lead times and cost savings in just 15 minutes or less.
Proudly operating with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation, After Market Aero Spares also operates with a strict NO CHINA Sourcing pledge, ensuring all products purchased are shipped in tandem with their applicable manufacturer trace documentation or qualifying certifications. Dedicated to only supplying premium NSN Part AFM120PS24 of the highest caliber, experience the simplicity of After Market Aero Spares when you are on the market for specific Xp Power Inc today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6120-01-600-9116 Item Description: POWER SUPPLY | 6120 | 016009116 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AFM120PS24 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.790 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 1.400 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.790 INCHES NOMINAL" |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 3000.0 METERS" |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING" |
AMQY | INSTALLATION DESIGN | FLOOR OR BENCH" |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT" |
ANRQ | FREQUENCY REGULATION PERCENT | 5.0 SINGLE POWER OUTPUT" |
APNX | INPUT VOLTAGE RATING | 90.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT" |
APPA | OUTPUT VOLTAGE RATING | 24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT" |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT" |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.0/+70.0 DEG CELSIUS" |
BGQR | OUTPUT WATTAGE RATING | 120.0 WATTS NOMINAL SINGLE POWER OUTPUT" |
BHQN | RECTIFICATION METHOD | INVERTER AC TO DC" |
CWGH | OUTPUT CURRENT RATING | 5.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT" |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL SINGLE POWER OUTPUT" |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT" |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR, PLUG SINGLE POWER OUTPUT" |
CWHM | INPUT CURRENT RATING | 1.0 AC AMPERES MINIMUM SINGLE OPERATING POWER RQMT AND 2.0 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT" |
CWHQ | INPUT CONNECTION TYPE | RECEPTACLE, ELECTRICAL SINGLE OPERATING POWER RQMT" |
CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT" |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | AFM120 AC-DC POWER SUPPLY" |
FEAT | SPECIAL FEATURES | 47.2-INCH OUTPUT CABLE" |
ABHP | OVERALL LENGTH | 6.790 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 1.400 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.790 INCHES NOMINAL" |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 3000.0 METERS" |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING" |
AMQY | INSTALLATION DESIGN | FLOOR OR BENCH" |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT" |
ANRQ | FREQUENCY REGULATION PERCENT | 5.0 SINGLE POWER OUTPUT" |
APNX | INPUT VOLTAGE RATING | 90.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT" |
APPA | OUTPUT VOLTAGE RATING | 24.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT" |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT" |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.0/+70.0 DEG CELSIUS" |
BGQR | OUTPUT WATTAGE RATING | 120.0 WATTS NOMINAL SINGLE POWER OUTPUT" |
BHQN | RECTIFICATION METHOD | INVERTER AC TO DC" |
CWGH | OUTPUT CURRENT RATING | 5.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT" |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL SINGLE POWER OUTPUT" |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT" |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR, PLUG SINGLE POWER OUTPUT" |
CWHM | INPUT CURRENT RATING | 1.0 AC AMPERES MINIMUM SINGLE OPERATING POWER RQMT AND 2.0 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT" |
CWHQ | INPUT CONNECTION TYPE | RECEPTACLE, ELECTRICAL SINGLE OPERATING POWER RQMT" |
CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT" |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | AFM120 AC-DC POWER SUPPLY" |
FEAT | SPECIAL FEATURES | 47.2-INCH OUTPUT CABLE" |
Warrantied inventory at competitive prices
Search the world’s largest inventory of electronic components by manufacturer, category or part number
We sell only warrantied and traceable parts
All inventory ready to ship from our sellers
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote