When you are in search of NSN parts under NSN 5963-00-007-5355 that your operations can depend on, allow us to show you how convenient the procurement process can be. On this page, you can find our list of featured parts like those with the NSN 5963-00-007-5355. Some of the top parts with this NSN include part numbers 2832000, and many others that are readily available for purchase. As a leading distributor of NSN parts, we go above and beyond industrial standards to guarantee the quality and authenticity of all our offerings. In addition, we are the only independent distributor that operates with a No China Sourcing pledge, meaning that we only source from trusted global manufacturers on our Approved Vendor List (AVL). Upon finding one or more items of interest, you may start the purchasing process today for parts under NSN 5963-00-007-5355 by submitting a completed RFQ form, and expect to receive a quote for your comparisons within 15 minutes!
Item Name | Electronic Module Standardized |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5963 Electronic Modules |
NIIN | 00-007-5355 (000075355) |
NCB Code | USA (00) |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
2832000 | navair ltd | electronic module standardized | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.620 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 1.950 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 0.590 INCHES NOMINAL" |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED" |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE" |
AKNA | INCLOSURE TYPE | ENCASED" |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC" |
AMQY | INSTALLATION DESIGN | MODULE" |
BHSX | III CIRCUIT CONSTRUCTION TYPE | SOLID STATE" |
BHTB | FREQUENCY PER CHANNEL | 150.0 KILOHERTZ NOMINAL OPERATING CHANNEL" |
BHTP | PULSE DURATION PER CHANNEL | 800.000 MILLISECONDS NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTP | PULSE DURATION PER CHANNEL | 800.000 MILLISECONDS NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTQ | PULSE RISE TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTQ | PULSE RISE TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTR | PULSE DECAY TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTR | PULSE DECAY TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTS | POLARITY PER CHANNEL | NEGATIVE 2ND OPERATING CHANNEL ERR-100" |
BHTS | POLARITY PER CHANNEL | POSITIVE 1ST OPERATING CHANNEL ERR-100" |
BHTT | PULSE REPETITION RATE PER CHANNEL | 800.000 KILOPULSES PER SECOND NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTT | PULSE REPETITION RATE PER CHANNEL | 800.000 KILOPULSES PER SECOND NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 22.000 VOLTS 1ST INPUT CHANNEL ERR-100" |
BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 22.000 VOLTS 2ND INPUT CHANNEL ERR-100" |
BHTZ | SIGNAL DATA TYPE PER CHANNEL | 1ST INPUT CHANNEL PULSE ERR-100" |
BHTZ | SIGNAL DATA TYPE PER CHANNEL | 2ND INPUT CHANNEL PULSE ERR-100" |
BJBP | CONNECTION TYPE AND LOCATION | CONNECTOR, PLUG BOTTOM" |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 1 CONNECTOR, PLUG EXTERNAL" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | -28.0 NOMINAL 1ST VOLTAGE ERR-100" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 28.0 NOMINAL 2ND VOLTAGE ERR-100" |
MARK | SPECIAL MARKINGS | GATE CKT ASSY" |
TEST | TEST DATA DOCUMENT | 10001-2832000 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW" |
TMDN | TYPE/MODEL DESIGNATION | RDQ" |
ABHP | OVERALL LENGTH | 2.620 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 1.950 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 0.590 INCHES NOMINAL" |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED" |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE" |
AKNA | INCLOSURE TYPE | ENCASED" |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC" |
AMQY | INSTALLATION DESIGN | MODULE" |
BHSX | III CIRCUIT CONSTRUCTION TYPE | SOLID STATE" |
BHTB | FREQUENCY PER CHANNEL | 150.0 KILOHERTZ NOMINAL OPERATING CHANNEL" |
BHTP | PULSE DURATION PER CHANNEL | 800.000 MILLISECONDS NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTP | PULSE DURATION PER CHANNEL | 800.000 MILLISECONDS NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTQ | PULSE RISE TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTQ | PULSE RISE TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTR | PULSE DECAY TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTR | PULSE DECAY TIME PER CHANNEL | 0.100 MICROSECONDS NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTS | POLARITY PER CHANNEL | NEGATIVE 2ND OPERATING CHANNEL ERR-100" |
BHTS | POLARITY PER CHANNEL | POSITIVE 1ST OPERATING CHANNEL ERR-100" |
BHTT | PULSE REPETITION RATE PER CHANNEL | 800.000 KILOPULSES PER SECOND NOMINAL 1ST INPUT CHANNEL ERR-100" |
BHTT | PULSE REPETITION RATE PER CHANNEL | 800.000 KILOPULSES PER SECOND NOMINAL 2ND INPUT CHANNEL ERR-100" |
BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 22.000 VOLTS 1ST INPUT CHANNEL ERR-100" |
BHTW | PULSE PEAK AMPLITUDE PER CHANNEL | 22.000 VOLTS 2ND INPUT CHANNEL ERR-100" |
BHTZ | SIGNAL DATA TYPE PER CHANNEL | 1ST INPUT CHANNEL PULSE ERR-100" |
BHTZ | SIGNAL DATA TYPE PER CHANNEL | 2ND INPUT CHANNEL PULSE ERR-100" |
BJBP | CONNECTION TYPE AND LOCATION | CONNECTOR, PLUG BOTTOM" |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 1 CONNECTOR, PLUG EXTERNAL" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | -28.0 NOMINAL 1ST VOLTAGE ERR-100" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 28.0 NOMINAL 2ND VOLTAGE ERR-100" |
MARK | SPECIAL MARKINGS | GATE CKT ASSY" |
TEST | TEST DATA DOCUMENT | 10001-2832000 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW" |
TMDN | TYPE/MODEL DESIGNATION | RDQ" |
5905-00-000-0136 (5905000000136) | 5905-00-001-1573 (5905000011573) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) | 5905-00-001-2814 (5905000012814) | 5905-00-001-2815 (5905000012815) | 5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) | 5905-00-001-2821 (5905000012821) | 5905-00-001-2822 (5905000012822) | 5905-00-001-2826 (5905000012826) |
Warrantied inventory at
competitive prices
Search the world’s largest
inventory of electronic components.
We sell only warrantied and
traceable parts
All inventory ready to ship
from our sellers
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote