When you are in search of NSN parts under NSN 5950-01-217-6349 that your operations can depend on, allow us to show you how convenient the procurement process can be. On this page, you can find our list of featured parts like those with the NSN 5950-01-217-6349. Some of the top parts with this NSN include part numbers 14060, 3L0125E001, 1892, and many others that are readily available for purchase. As a leading distributor of NSN parts, we go above and beyond industrial standards to guarantee the quality and authenticity of all our offerings. In addition, we are the only independent distributor that operates with a No China Sourcing pledge, meaning that we only source from trusted global manufacturers on our Approved Vendor List (AVL). Upon finding one or more items of interest, you may start the purchasing process today for parts under NSN 5950-01-217-6349 by submitting a completed RFQ form, and expect to receive a quote for your comparisons within 15 minutes!
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
NIIN | 01-217-6349 (012176349) |
NCB Code | USA (01) |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
14060 | magnespec inc | transformer power | Avl | RFQ |
3L0125E001 | other | transformer power | Avl | RFQ |
1892 | standard industries | transformer power | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL" |
ACZB | FREQUENCY RATING | 18.5 KILOHERTZ MINIMUM AND 30.0 KILOHERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ADAV | OVERALL DIAMETER | 1.900 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 3 PRIMARY AND 2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 19.0 MILLIAMPERES AC MINIMUM AND 21.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND PRIMARY" |
CRBZ | WINDING OPERATING CURRENT | 19.0 MILLIAMPERES DC MINIMUM AND 21.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.66 AMPERES DC MINIMUM AND 2.94 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 5.99 AMPERES DC MINIMUM AND 6.62 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 16.41 AC VOLTS MINIMUM AND 17.07 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 21.32 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS MINIMUM AND 37.56 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 6.49 AC VOLTS MINIMUM AND 6.82 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 60.70 AC VOLTS MINIMUM AND 64.40 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 18 PIN" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 1.000 INCHES NOMINAL" |
ACZB | FREQUENCY RATING | 18.5 KILOHERTZ MINIMUM AND 30.0 KILOHERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ADAV | OVERALL DIAMETER | 1.900 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 3 PRIMARY AND 2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 19.0 MILLIAMPERES AC MINIMUM AND 21.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND PRIMARY" |
CRBZ | WINDING OPERATING CURRENT | 19.0 MILLIAMPERES DC MINIMUM AND 21.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.66 AMPERES DC MINIMUM AND 2.94 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 5.99 AMPERES DC MINIMUM AND 6.62 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 16.41 AC VOLTS MINIMUM AND 17.07 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 21.32 AC VOLTS MINIMUM AND 22.20 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS MINIMUM AND 37.56 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 6.49 AC VOLTS MINIMUM AND 6.82 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 60.70 AC VOLTS MINIMUM AND 64.40 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 18 PIN" |
5905-00-000-0136 (5905000000136) | 5905-00-001-1573 (5905000011573) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2812 (5905000012812) |
5905-00-001-2813 (5905000012813) | 5905-00-001-2814 (5905000012814) | 5905-00-001-2815 (5905000012815) | 5905-00-001-2818 (5905000012818) |
5905-00-001-2819 (5905000012819) | 5905-00-001-2821 (5905000012821) | 5905-00-001-2822 (5905000012822) | 5905-00-001-2826 (5905000012826) |
Warrantied inventory at
competitive prices
Search the world’s largest
inventory of electronic components.
We sell only warrantied and
traceable parts
All inventory ready to ship
from our sellers
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote